Contactless safety interlocking with encoded striker for "casing / light door" :
Contactless "door lock" encoded detection
Unlock command with just one contact during serialization of products
Cycle before dangerous failure: B10d = 1,000,000 at 200mA
Bolt travel: 9 mm
Bolt diameter: 12 mm
Shearing strength: 1000 N
Distance between latch and lock: 0 to 4 mm (adjustable when assembling, recommended to 4 mm)
Maximum lateral displacement between strike and lock: +/- 0.8 mm
Maximum angular displacement between strike and lock: +/- 5°
Safety locking contacts: 2 x NO 0.4A /24V redundant and
Unlock command: PLC-compatible (12~30 VDC/2~5 mA)
Diagnostic error: Auxiliary output indicates unlocking
Reset: on command
Infinite automatic offset control when connected in series: minimal consumption
Auxiliary release: key supplied (free key in lock mode; captive key in release mode)
Attachment: 4 M4 screws (screw covers included)
Mounting position: 1
Material: PA6 fiberglass reinforced
Electrical connection: very resistant 50 cm or 130 cm PUR UL20549 cord with M12 connector or cable (contact us)
Water resistance: IP 65
Ambient temperature: -5°C to +40°C.
Marking: screen printed + serial no. for traceability