No power or under-voltage locking on machine casings
Compatible with grooved profiles
Machine protection closing control for harsh environments
Antimicrobial handle available
Level of performance with AWAX controller: up to PL = e
Safety category: up to 4 with an AWAX controller
Time before dangerous failure: MTTFd = 100 years
Maximum detection activation distance: 2 mm
Holding force: up to 936 N (ref. version + OX-R) or up to 820 N (ref. version + OX-E)
Safety contacts/diagnostics: 2 x NO 400mA max/24V redundant and 1 x PNP 250mA
Detection encoding: mono-code inviolable
Reset: automatic or controlled (ref. + OP)
Housing mount: 4 tamper-proof M6 screws (optional ref: BH6) and screw covers
Handle attachment: 2 M6 screws
Mounting position: 2
Casing material: INOX 316L mirror polished (OX version)
Suction cup material: Magnetic INOX (ref. + OX)
Electrical Connection: 50cm PUR cord with M12 connector
Water resistance: IP 67/68
Temperature: -25°C to +50°C (thermal protection for suction cups in case of overheating due to a persistent command)
Marking: laser engraving with mechanically punched serial number for permanent traceability