ANATOM78S PL EEX
Position control on doors / casings in ATEX :
Contactless coded electronic sensor
ATEX zone 0/20 (PL version) or 1/21 (OX version)
 
Atex safety :
ATEX standards
EN 60079-0
EN 60079-11
EN 60079-25
EN 60079-26
ATEX marking for PL version
II 1 GD
Ex ia IIC T4 Ga
Ex ia IIIC T135°C Da
Product used in combination with AWAX26XXL-EEX box
ATEX marking for OX version
II 2 GD
Ex ia IIC T4 Gb
Ex ia IIIC T135°C Db
Product used in combination with AWAX26XXL-EEX box
 
Machine Safety :
Level of performance with AWAX controller: up to PL = e
Safety category: 4 with AWAX controller
Time before dangerous failure: MTTFd = 277 years
Max. activation distance: 10 mm, 4 mm hysteresis
Safety contacts/diagnostics: NO 2 x 50 mA/12V redundant and
1 x PNP 15mA/12V contact
Shock / vibrations: 30 G
Detection encoding: mono-code inviolable
Indicator: LED indicates code recognition
Reset: automatic
Total number of connectable sensors in series: 0
Attachment: 4 tamper-proof M4 screws (optional ref: BH4)
Mounting position: 2 (double wall brackets)
Material: PA6 (PL version) or INOX 316L mirror polished (OX version)
Electrical connection: 12m or more on request
Water resistance: IP 67
Ambient temperature: -20°C to +40°C.
Surface temperature: 135°C (dust) and T4 (gas)
Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability
Certification: INERIS 06ATEX0007X