Important information on MSD (Musculoskeletal disorders) :
Comprises conditions on all soft tissues around joints: muscles, tendons and sheaths, nerves and vessels. The most common health problem in France, requiring the most work stoppages. The two-hand KOB101Ti control offers unparalleled user comfort by reducing MSD.
Two-hand dual-technology touch control button for enhanced safety :
Dynamic detection of approaching hand - even wearing gloves
Fraud and MSD reduction system
Capacitive touch technology and optical button
Performance level with COM3C controller: PL = e
Safety category with COM3C: IIIC (EN 574), 4 (ISO 13849-1)
Safety Integrity Level with COM3C: SIL 3
Time before dangerous failure: MTTFd = 100 years
Activation distance: with touch (0 force = MSD reduction)
Safety contacts: 1 x PNP NO/50mA OSSD and 1 x PNP NF/50mA OSSD
Diagnostics: fraud, simultaneity, shorting contacts with illuminated ring for multifunctions
Reset: automatic with two buttons correctly activated
Attachment: 2 or 6 M3 screws (hidden by trimming)
Mounting position: 1
Material: TR90UV yellow
Electrical connection: terminal 6 lanes 1.5mm² push screwless
Water resistance: IP 67 with silicone seal on the trimming
Temperature: -25°C to +60°C
Marking: screen printed + serial no. for traceability
Recommendations: use gloves in accordance with EN 388
Copyright © 2014 EE CONTROLS SAFETY
Email : inform@eecontrols.com
Telephone : (845) 278-5777