Example of application :
1) Unlocking a door if the pressure on a pneumatic circuit drops below 2 bars
- Level of Performance required = "PL c" in accordance with ISO 13849-1
- Gas temperature = 20°C
- Type of gas = air with lubricant
- Pressure controller reference = PS-Nb-NH-P2 (2B) -CAT1
- Interlock reference = VIGILGUARD-SFR
2) Vacuum control trays with film
- Level of Performance required = "PL c" in accordance with ISO 13849-1
- Gas temperature = 100°C
- Type of gas = air + steam + vegetable oil
- Pressure controller reference = VS-Nh-S-V900 (-0.9B) - CAT1
3) Stop the machine if the pressure drops below 2 bars
- Level of Performance required = "PL e" in accordance with ISO 13849-1
- Gas temperature = -30°C
- Type of gas = air
- Pressure controller reference = PPS-Nh-NT-P2 (2B) - CAT1
- Extension to PL e = AWAX 26XXL
Gas and fluid pressure control :
Redundant low and high pressure control with channel synchronization
Pressure control from 0.1b to 300b (to be defined when ordering)
Vacuum control from -0.2b to -0.9b (to be defined when ordering)
Level of performance with AWAX controller: up to PL = e
Level of performance only: PL = c
Safety category with an external controller: up to 4
Integrated security' level with an external controller: up to SIL 3
Cycle before dangerous failure: B10d = 100,000
Safety contacts: 2 x NO 2A/50V
Auxiliary contact: 1 x PNP NF 2A/50V
Reset: automatic
Attachment: 4 x M4 flat head or domed screws
Mounting position: 1
Material: Polycarbonate
Electrical connection: PUR UL20549 very durable 50 cm cord with M12 connector
Pneumatic connection: G1/4 and 8 mm quick connector
Water resistance: IP 65
Ambient temperature: -25°C to +60°C
Fluid temperature: -40°C to 140°C (specify temperature and the nature of the fluid in the order)
Marking: label + serial no. for traceability