Examples of machine safety applications with SM1-OX-EOP :
Under voltage lock-out
- The safety contacts open upon application of the release voltage
- The door remains always closed
- The auxiliary line closes upon door opening by the operator
- On request, we can supply the transmitter with a fixed counter-plate, with a silicone seal for food industry compatibility
Offset M12 connectors for stainless steel products :
Our experience has led us to conclude that M12 connectors mounted directly onto sensors cause reliability issues during washing as well as with machine vibrations. On the other hand, M8 connectors can be quite fragile, especially on products requiring frequent removal.
Our solution of a molded M12 cord that is offset by 50 cm allows for the connector part to be housed in the cable trunkings, providing protection from washing jets and mechanical stress.
Electromagnetic safety lock control with 580 N force :
No power or under-voltage locking on machine casings
Machine protection closing control for harsh environments
100% stainless steel version available
Level of performance with AWAX controller: up to PL = e
Safety category: up to 4 with AWAX controller or PLC SIL 3
Time before dangerous failure: MTTFd = 100 years
Maximum detection activation distance: 2 mm
Holding force: up to 580 N
Safety contacts/diagnostics: 2 x NO 400mA max/24V redundant and 1 x PNP 250mA
Detection encoding: mono-code inviolable
Indicator: LED
Reset: automatic or controlled (ref. + OP)
Attachment: 4 M4 screws (inviolable on new generation and optional ref.: BH4)
Mounting position: 1
Casing material: INOX316L mirror polished (OX version) or POLYCARBONATE (PL version)
Suction cup material: INOX (SM1 + OX) or steel (SM1 + PL-AC)
Electrical connection: the M12 metal base will be replaced with a 50cm PUR cord with an M12 connector on the new generation
Water resistance: IP 67/68
Temperature: -25°C to +50°C.
Marking: laser engraving with mechanically punched serial number for permanent traceability (OX version) or screen printed serial number for traceability (PL version)
Copyright © 2014 EE CONTROLS SAFETY
Email : inform@eecontrols.com
Telephone : (845) 278-5777