The choice of the communication protocol
1) RS232C :
- Point-to-point link
- Maximum length of cable 15m
- ASCII protocol or Modbus
2) RS485 :
- Multipoint connection up to 31 slaves to one master.
- Maximum length of cable 15m
- ASCII protocol or Modbus
- POLLING method: the master polls each slave successively in an infinite loop
- "on demand" method when the "strobe" output goes to one (presence of tag), the master polls the drive that stored the tag data.
RFID tag reader/writer for PLC :
Ultra-compact, very thin, plugs directly into the PLC
Process management, sorting ... etc.
MODBUS RS485 (RTU) or RS232 (ASCII) network
Life cycle: 20 years
Max activation distance: up to 45 mm
Contact: 1 x strobe PNP /1 RS485 (base + 485) or RS232 (base + 232)
Detection encoding: infinite
Indicator: LED indicates code recognition
Reset: automatic
Mounting: M30 nut provided
Mounting position: 1
Material: TR90UV
Electrical connection: screwless terminal
Sealing: IP 67
Temperature: -20 °C to +60 °C
Marking: screen printing
Options:
- Stainless steel badge holder: AXKEF/CARD HOLDER
- badge nail, screw, plate screw, key chain, card ... etc.
Copyright © 2014 EE CONTROLS SAFETY
Email : inform@eecontrols.com
Telephone : (845) 278-5777